350 Tong Link Extension
$275,000.00$290,000.00 (-5%)
350 Tong Link Extension engine drives the dual stage pump at a setting of 2100 rpm. The pump draws hydraulic fluid from the tank and delivers hydraulic fluid up to 2500 psi on the pressure line, adjustable at the relief valve (preset at 2500 psi). The 2500 psi setting is the maximum recommended output pressure for the standard pump. Theoretically the unit could produce more at full engine rated output, but pump life will be shortened, possibly dramatically. The pump delivers 65 GPM at 1000 psi and 27 GPM at the engine’s maximum speed of 2500 psi. See the Adjustment section on page 16 for how to change the relief valve setting.
Part No:
TEXP914l06-AIR
Options:
Air or Electric Start
Item | Size (inches) | Dry Weight (lbs) | Full Weight (lbs) |
---|---|---|---|
Power Unit | 86 – 52 – 59 | 3709 | 4821 |
Power Unit-Turbo | ‘110-1/2 – 52 – 59 | 4092 | 5204 |
Item | Power (hp) | Speed (rpm) | Torque (ft/lbs) | Oil/Filter Change (hrs) | Fuel Consumption |
---|---|---|---|---|---|
Deutz Air Cooled Diesel Engine – Air Start | 119 | 2500 | 255 | 500** | 6 gph*** |
Deutz Air Cooled Diesel Engine – Electric Start | 85 | 1500 | 295 | 500** | 6 gph*** |
** Under severe condition – do every 250 hours | |||||
*** Approximately at maximum output |